Answer in amps
- Load: 1,500 W
- Headroom: 300 W
- Watts
- 1,500 W
- Amps
- 12.5 A
- Volts
- 120 V
Within the rating: 12.5 A, 83% of the 15 A rating.
The breaker’s number is its rating in amps.
Watts, amps and volts
Amps = watts ÷ volts, and watts = volts × amps. A 1,500 W heater on a US 120 V supply draws 12.5 A; a 3,000 W kettle on the UK’s 230 V draws about 13 A. That is why a UK 13 A plug, socket or extension lead tops out at about 3,000 W (13 × 230 = 2,990 W; Electrical Safety First gives 3,000 W as the maximum rating of a wall socket), and a US 15 A circuit at 1,800 W (15 × 120), counting everything plugged into that circuit, not just one outlet.
Answer in amps
Within the rating: 12.5 A, 83% of the 15 A rating.
The breaker’s number is its rating in amps.
For a household supply, power in watts is the voltage times the current: W = V × A. Turn it round for the other two: A = W ÷ V and V = W ÷ A. For heaters, kettles, toasters and old-style bulbs, which simply turn electricity into heat, that is all there is to it. Motors and electronics can draw a little more current than watts ÷ volts suggests, so when an appliance’s rating label gives amps, use the label’s amps rather than working them out.
| Watts | At 120 V (US) | At 230 V (UK) | At 240 V (US large appliances) |
|---|---|---|---|
| 100 W | 0.83 A | 0.43 A | 0.42 A |
| 500 W | 4.17 A | 2.17 A | 2.08 A |
| 700 W | 5.83 A | 3.04 A | 2.92 A |
| 1,000 W | 8.33 A | 4.35 A | 4.17 A |
| 1,500 W | 12.5 A | 6.52 A | 6.25 A |
| 1,800 W | 15 A | 7.83 A | 7.5 A |
| 2,000 W | 16.67 A | 8.7 A | 8.33 A |
| 2,400 W | 20 A | 10.43 A | 10 A |
| 3,000 W | 25 A | 13.04 A | 12.5 A |
| 4,500 W | 37.5 A | 19.57 A | 18.75 A |
In the US, homes are fed two 120 V wires and a neutral; ordinary circuits use one of them, and big appliances such as water heaters, electric ranges and clothes dryers use both for 240 V, as the Electrical Safety Foundation International explains. The Red Cross puts it simply: most household devices run on 120 volts. In Great Britain the declared supply is 230 V, allowed to vary from 10% above to 6% below (about 216 to 253 V) under the Electricity Safety, Quality and Continuity Regulations 2002. Use the nominal figure: 120, 240 or 230 V.
Electrical Safety First, the UK electrical safety charity, says a standard plug should meet BS 1363 (marked on the back) and its fuse BS 1362. Plug fuses are now standardised at 3 A or 13 A, with 5 A still found in some older equipment. As a general guide, an appliance rated from 700 to 3,000 W should have a 13 A fuse; its 3 A examples are table lamps, televisions and computers. Replace a fuse only with one of the same rating.
Most extension leads are rated 13 A, so the whole lead can carry no more than a single wall socket: about 3,000 W in total, however many sockets it has. Some older leads are rated 10 A, and a cable reel left wound up may be rated as low as 3 or 4 A, which is why Electrical Safety First says to unwind it fully. The extension lead calculator adds up what’s on one lead for you.
The number on a breaker is the circuit’s rating in amps. A 15 A circuit at 120 V carries 1,800 W at its rating, a 20 A circuit 2,400 W. The catch is that one circuit usually feeds several outlets and lights, and the breaker sees all of them together, so the check is on everything running on that circuit, not on one outlet. Electricians also leave a margin when a heavy load runs for hours, under the National Electrical Code (NFPA 70). The rules depend on the edition your state has adopted and we couldn’t check the current wording on a free public page, so the calculator doesn’t build that margin in: if a heater or another heavy load will run for hours on one circuit, ask a licensed electrician what that circuit can take.
Extension cords have their own ratings, marked on the cord. The US Consumer Product Safety Commission says a cord’s wattage rating should exceed the total wattage of everything plugged into it, and the Electrical Safety Foundation International says extension cords should only be used on a temporary basis and should meet or exceed the power needs of what is plugged in.
This page does arithmetic; it isn’t a substitute for an electrician who can see your wiring. Electrical Safety First’s danger signs are a good list: a smell of hot plastic or burning near a socket or plug, sparks or smoke, scorch marks, damaged or frayed cables, and fuses that blow or breakers that trip for no obvious reason. Unplug, and get it checked. If you rely on extension leads and adaptors every day, Electrical Safety First suggests having more wall sockets fitted by a registered electrician instead.
All checked on 5 November 2026.
About 3,000 W. 13 A × 230 V = 2,990 W, and Electrical Safety First gives 3,000 W as the maximum rating of a wall socket. An extension lead rated 13 A has the same limit for everything plugged into it together.
12.5 A on a 120 V US supply, and about 6.5 A on the UK’s 230 V. Amps = watts ÷ volts. On a 15 A US circuit that leaves only 2.5 A, or 300 W, for everything else on the same circuit.
1,800 W at 120 V at its rating, for everything on that circuit together. A heavy load that runs for hours, such as a heater, calls for a margin under the National Electrical Code, so ask a licensed electrician before running one alongside other loads.
Electrical Safety First says plug fuses are standardised at 3 A or 13 A: 13 A for appliances rated 700 to 3,000 W, 3 A for things like lamps, TVs and computers. Always replace a fuse with one of the same rating, and check the appliance’s instructions if unsure.
Multiply the amps by the volts: 10 A at 230 V is 2,300 W, and 10 A at 120 V is 1,200 W. For a motor, use the watts on its rating label if it gives them.